When a supplier says a wall panel is "fire rated," the next question decides everything: rated under which standard? B1 (China, GB 8624), Class A (US, ASTM E84) and Euroclass B-s1,d0 (Europe, EN 13501-1) come from three different test methods, run by different labs, on different scales. A report from one system does not transfer to the others.
All three describe reaction to fire of the assembled product — substrate plus decorative film plus adhesive — not of one layer alone.
The test methods differ fundamentally: a tunnel test, cone-calorimetry-based procedures and China's GB methods rank materials on different scales. A panel tested to B1 in China has valid B1 data — but whether it would achieve Class A under ASTM E84 is a question only an ASTM E84 test can answer.
If your specifier accepts "technical equivalence" between systems, get that acceptance in writing from them — most code officials and insurers will not accept it, and a certificate cover page is not a substitute for a report.
Which standard is the certificate under? Get the exact standard number, test lab and report date.
Q: Is B1 the same as Class A?
A: No. They come from different test methods in different countries. A B1 result documents performance under GB 8624; it does not document ASTM E84 performance.
Q: The panels are B1-rated — can I use them in a US project?
A: Only if your approval path accepts the GB 8624 documentation. If the project falls under US code, request ASTM E84 testing on the exact specification before approval, and get your specifier's written position on equivalence if you rely on it.
Q: Does the film or the substrate carry the fire rating?
A: Neither alone — the rating applies to the assembled product as tested. That is why you should confirm the tested combination matches your order.
Q: What fire document should I collect before placing the order?
A: Standard number, test lab, report date, and the exact product combination tested. Four lines that turn "fire rated" from a marketing word into a checkable fact.